Idea Statica
  • Steel
  • Concrete
  • BIM & Workflows
  • Support & Learning
  • Pricing
  • Company
  • Steel overview
  • Connection design
  • Member design
  • Parametric design
  • Steel case studies
  • Concrete overview
  • Walls and D-regions
  • Anchoring design
  • Concrete case studies
  • BIM Overview
  • Supported integrations
  • Checkbot
  • Viewer
  • APIs
  • Support Center
  • E-learning & certification
  • Blog
  • Downloads & Licensing
  • Plans
  • Free community tool
  • Enterprise customers
  • Students & educators
  • How much will you save?
  • About us
  • Contact
  • Research & development
  • Authorized resellers
  • Meet our customers
  • Career
  • Steel
    Steel overviewConnection designMember designParametric designSteel case studies
  • Concrete
    Concrete overviewWalls and D-regionsAnchoring designConcrete case studies
  • BIM & Workflows
    BIM OverviewSupported integrationsCheckbotViewerAPIs
  • Support & Learning
    Support CenterE-learning & certificationBlogDownloads & Licensing
  • Pricing
    PlansFree community toolEnterprise customersStudents & educatorsHow much will you save?
  • Company
    About usContactResearch & developmentAuthorized resellersMeet our customersCareer
14-Day Trial
14-Day Trial
  • Steel
  • Concrete
  • BIM & Workflows
  • Support & Learning
  • Pricing
  • Company

Subscribe to our newsletter

Company

  • About us
  • Partners
  • Careers
  • Patent

Resources

  • Customer projects
  • Case studies
  • Connection Library
  • Verification books

Legal

  • EULA
  • Privacy policy
  • California Privacy
  • TOS Viewer
  • Licensing

Help

  • Contact
  • Quote request
  • Resellers
  • Downloads
FacebookInstagramLinkedInYouTube

© IDEA StatiCa 2009-2026

Trusted and used worldwide by engineers, fabricators & consultants.

Support CenterKnowledge Base ArticlesCapacity design according to Canadian standards
Advanced analysis types for your steel structures
Seismic analysis in IDEA StatiCa Connection
Qualification checks of seismic prequalified connections for AISC
Prequalified Steel Connections (AISC) - Summary, Conclusion, and Recommendations
Steel connection capacity design
Capacity design (EN)
Capacity design (AISC)
Capacity design according to Canadian standards
Capacity design according to Australian standards
Capacity design according to Indian Standard
Capacity design according to Hong Kong Code
Capacity design according to Chinese standard
Capacity design according to Russian standards
Capacity design is a part of the seismic check and ensures that the joint has sufficient deformation capacity. IDEA StatiCa - engineering software for the structural design of steel connections and beams.
Connection designSteelKnowledge baseConnectionCBFEM

Capacity design according to Canadian standards

This article is also available in
ENCZDEESFRITPTNLHUROKRPLTHTRVIZH

Capacity design is a part of seismic check and ensures that the joint has sufficient deformation capacity.

The objective of capacity design is to confirm a building undergoes controlled ductile behaviour in order to avoid collapse in a design-level earthquake. Plastic hinge is expected to appear in dissipative item and all non-dissipative items of the joint must be able to safely transfer forces due to the yielding in the dissipative item. The dissipative item is usually a beam in moment resisting frame but it may also be e.g. an end plate. The resistance factor is not used for dissipative items. Two factors are assigned to the dissipative item:

  • Ry = 1.1 – overstrength factor – S16-14, Cl. 27.1.7; editable in materials
  • Cpr = 1.1 – strain-hardening factor – S16-14, Cl. 27.2.2; it is recommended to apply for beam as a dissipative item in moment resisting frame

The material diagram is modified according to the following figure:

The increased strength of the dissipative item allows for the input of loads that cause the plastic hinge to appear in the dissipative item. In the case of moment resisting frame and beam as the dissipative item, the beam should be loaded by My = CprRyFyWpl,y and corresponding shear forceVz = –2 My,Ed / Lh, where:

  • Fy – yield strength
  • Wpl,y – plastic section modulus
  • Lh – distance between plastic hinges on the beam

In case of asymmetric joint, the beam should be loaded by both sagging and hogging bending moments and their corresponding shear forces.

The plates of dissipative items are excluded from check.

Related articles

Components are designed according to the Canadian standard (CISC) S16-14 Design of steel structures and CSA A23.3 Structural design of welded and bolted steel connections and steel beam to column connection details.
  • Steel
  • CSA (Canada)
  • CBFEM
  • Connection
  • +4
  • Steel
  • CSA (Canada)
  • CBFEM
  • Connection

Theoretical background

Check of steel connection components (CSA)

Read more
The joints are classified according to rotational stiffness to rigid, semi-rigid, and pinned. IDEA StatiCa - engineering software for the structural design of welded and bolted steel connections.
  • Steel
  • Connection
  • CBFEM
  • Rotational stiffness
  • Stiffness
  • CSA (Canada)
  • +6
  • Steel
  • Connection
  • CBFEM
  • Rotational stiffness
  • Stiffness
  • CSA (Canada)

Knowledge base

Steel joint classification according to Canadian standards

Read more
Capacity design analysis to deal with seismics
  • Steel
  • Connection
  • AISC (USA)
  • CBFEM
  • Capacity design
  • Moment Connection
  • Seismicity
  • EN (Eurocode)
  • +8
  • Steel
  • Connection
  • AISC (USA)
  • CBFEM
  • Capacity design
  • Moment Connection
  • Seismicity
  • EN (Eurocode)

Knowledge base

Seismic analysis in IDEA StatiCa Connection

Read more