Idea Statica
  • Steel
  • Concrete
  • BIM & Workflows
  • Support & Learning
  • Pricing
  • Company
  • Steel overview
  • Connection design
  • Member design
  • Parametric design
  • Steel case studies
  • Concrete overview
  • Walls and D-regions
  • Anchoring design
  • Concrete case studies
  • BIM Overview
  • Supported integrations
  • Checkbot
  • Viewer
  • APIs
  • Support Center
  • E-learning & certification
  • Blog
  • Downloads & Licensing
  • Plans
  • Free community tool
  • Enterprise customers
  • Students & educators
  • How much will you save?
  • About us
  • Contact
  • Research & development
  • Authorized resellers
  • Meet our customers
  • Career
  • Steel
    Steel overviewConnection designMember designParametric designSteel case studies
  • Concrete
    Concrete overviewWalls and D-regionsAnchoring designConcrete case studies
  • BIM & Workflows
    BIM OverviewSupported integrationsCheckbotViewerAPIs
  • Support & Learning
    Support CenterE-learning & certificationBlogDownloads & Licensing
  • Pricing
    PlansFree community toolEnterprise customersStudents & educatorsHow much will you save?
  • Company
    About usContactResearch & developmentAuthorized resellersMeet our customersCareer
14-Day Trial
14-Day Trial
  • Steel
  • Concrete
  • BIM & Workflows
  • Support & Learning
  • Pricing
  • Company

Subscribe to our newsletter

Company

  • About us
  • Partners
  • Careers
  • Patent

Resources

  • Customer projects
  • Case studies
  • Connection Library
  • Verification books

Legal

  • EULA
  • Privacy policy
  • California Privacy
  • TOS Viewer
  • Licensing

Help

  • Contact
  • Quote request
  • Resellers
  • Downloads
FacebookInstagramLinkedInYouTube

© IDEA StatiCa 2009-2026

Trusted and used worldwide by engineers, fabricators & consultants.

Support CenterKnowledge Base ArticlesBolts are too close to plate edge
Advanced analysis types for your steel structures
Bolts are too close to plate edge
Traffic lights for forces in bolts
Prying and high tension force in bolts
Bolt force distribution in end-plate beam-to-column connection
Bolt shear force calculated per shear plane
Through-bolts in hollow sections: design them as pins, not bolts
Bolt bearing distances for Eurocode
Warnings for welds and bolts connecting the same plates
Slip resistance check update according to SP 16
Detailing improvements for bolts and welds in Eurocode
Angle to the grain of the steel-to-timber connections
Filler plate (packing plate) recognition
Smooth results with precise meshing
Code-check of bolts and preloaded bolts (EN)
Code-check of bolts and preloaded bolts (AISC)
Code-check of bolts and preloaded bolts according to Canadian standards
Code-check of bolts and preloaded bolts according to Australian standards
Code-check of bolts and preloaded bolts according to Chinese standard
Code-check of bolts according to Hong Kong Code
Code-check of bolts and preloaded bolts according to Hong Kong Code
Code-check of bolts according to Indian standard
Code-check of preloaded bolts according to Indian standards
Code-check of bolts and preloaded bolts according to Russian standards
Bolts are too close to plate edge
Connection designSteelKnowledge baseConnectionBolts

Bolts are too close to plate edge

This article is also available in
ENCZDEESFRITPTNLHUROKRPLTHTRVIZH

"Bolts are too close to plate edge or outside of the connected plate" is an error message you might receive during your steel connection modeling process. There are two most common mistakes in Manufacturing operations causing this error.

Bolts are too close to the edge of a plate

This generally means that the mesh could not be generated around the bolt’s hole as there is not enough space for it. For the bolt’s hole of a diameter d0, there must be a space greater than d0/2 between the hole’s edge and the plate’s edge. Therefore, the center of the bolt must be placed further than d0 distance from the plate’s edge.

E.g. for bolt size M16, the diameter of the hole d0 is 18 mm, and the position of the bolt must be greater than 18 mm from the edge of any plates that it intersects.

With the increased distance of the bolt from the edge, the calculation can be performed.

Bolts are not associated with the correct plate

Even though the bolts in the following figure may look as correctly placed, the error occurred. The reason is that all 8 bolts cannot be defined in one manufacturing operation, as they are connecting the stiffening plates with two different members. The left quartet connects the stiffening plates with the B1 member while the right quarter of bolts connects the stiffening plates with the B2 member.

Therefore, it is necessary to separate the bolts into two manufacturing operations. In the first step, define bolt grid GR1 of four bolts for member B1 with the appropriate position of bolts.

Copy the operation, change Member 2 to B2, and adjust the bolt positions.

Now, the bolt groups are associated with the correct plates and the calculation can be performed.

Note: To design both-sided splices efficiently, it is better to use the Splice manufacturing operation.

See the video explaining the error "Bolts are too close to plate edge".

Related articles

Bolted steel connection
  • Steel
  • Bolts
  • Connection
  • +3
  • Steel
  • Bolts
  • Connection

Blog post

Bolts and bolted connections

Read more
How to define pre-loaded bolts
  • Steel
  • Connection
  • AISC (USA)
  • Bolts
  • Contacts
  • EN (Eurocode)
  • +6
  • Steel
  • Connection
  • AISC (USA)
  • Bolts
  • Contacts
  • EN (Eurocode)

Knowledge base

How to define preloaded bolts

Read more
How to set position of bolts
  • Steel
  • Connection
  • Bolts
  • Manufacturing operations
  • +4
  • Steel
  • Connection
  • Bolts
  • Manufacturing operations

Knowledge base

How to set position of bolts

Read more
Prying and high tension force in bolts
  • Steel
  • Connection
  • CBFEM
  • Bolts
  • Stress/strain
  • +5
  • Steel
  • Connection
  • CBFEM
  • Bolts
  • Stress/strain

Knowledge base

Prying and high tension force in bolts

Read more