Idea Statica
  • Steel
  • Concrete
  • BIM & Workflows
  • Support & Learning
  • Pricing
  • Company
  • Steel overview
  • Connection design
  • Member design
  • Parametric design
  • Steel case studies
  • Concrete overview
  • Walls and D-regions
  • Anchoring design
  • Concrete case studies
  • BIM Overview
  • Supported integrations
  • Checkbot
  • Viewer
  • APIs
  • Support Center
  • E-learning & certification
  • Blog
  • Downloads & Licensing
  • Plans
  • Free community tool
  • Enterprise customers
  • Students & educators
  • How much will you save?
  • About us
  • Contact
  • Research & development
  • Authorized resellers
  • Meet our customers
  • Career
  • Steel
    Steel overviewConnection designMember designParametric designSteel case studies
  • Concrete
    Concrete overviewWalls and D-regionsAnchoring designConcrete case studies
  • BIM & Workflows
    BIM OverviewSupported integrationsCheckbotViewerAPIs
  • Support & Learning
    Support CenterE-learning & certificationBlogDownloads & Licensing
  • Pricing
    PlansFree community toolEnterprise customersStudents & educatorsHow much will you save?
  • Company
    About usContactResearch & developmentAuthorized resellersMeet our customersCareer
14-Day Trial
14-Day Trial
  • Steel
  • Concrete
  • BIM & Workflows
  • Support & Learning
  • Pricing
  • Company

Subscribe to our newsletter

Company

  • About us
  • Partners
  • Careers
  • Patent

Resources

  • Customer projects
  • Case studies
  • Connection Library
  • Verification books

Legal

  • EULA
  • Privacy policy
  • California Privacy
  • TOS Viewer
  • Licensing

Help

  • Contact
  • Quote request
  • Resellers
  • Downloads
FacebookInstagramLinkedInYouTube

ยฉ IDEA StatiCa 2009-2026

Trusted and used worldwide by engineers, fabricators & consultants.

Support CenterVerification examplesDouble angle cleat connection
Double angle cleat connection
SteelVerificationsAS (Australia)Connection

Double angle cleat connection

This article is also available in
ENCZDEESFRITPTNLHUROKRPLTHTRVIZH

In this verification article, a double angle cleat connection is being investigated according to AS 4100.

Type of connection: Double angle cleat connection

Unit system:ย Metric

Designed acc. to:ย AS 4100

Investigated: Bolts, base metal

Plate material:ย Grade 300

Bolts: M20 Grade 8.8

Example taken from:ย B. Kirke, I.H. Al-Jamel.ย Steel Structures:ย Design Manual To ASย 4100, 2004 โ€“ Chapter 9.4.1.1

Geometry

Beam UB 406ร—178ร—60 is connected to column UC 254ร—254ร—89 by two angles L100ร—6.

Double angle cleat connection

M20 bolts grade 8.8 are selected with the pitch of 70ย mm.

Applied load

The beam is loaded by shear force 190 kN. To be conservative, for the design of bolts at the beam web, the shear force should be at the position of the column face so that the group of bolts is loaded also by bending moment โ€“ select forces in position 130 mm. For the design of angles and the group of bolts at the column face, the shear force should be applied at the position of centre of gravity of the bolts at the beam web โ€“ select forces in bolts.

Comparison between manual calculation and IDEA StatiCa

The results of B. Kirke, I.H. Al-Jamel.ย Steel Structures:ย Design Manual To ASย 4100, 2004 โ€“ Chapter 9.4.1.1 are used as manual calculation.

Connection of web of beam

The group of bolts are loaded by the shear force 190 kN and bending moment resulting from the distance between the applied load at the face of the column and the centre of gravity of the bolt group at the beam web, 190 kN ร— 65 mm = 12.35 kNm. The maximum force in bolt was calculated as 71.1 kN. Results of IDEA is in the figure below. The arrows show the reaction of the plate on the bolt force.

The maximum force is in the bolt B4, each shear plane transfers 36.3 kN, i.e. the whole bolt transfers 2 ร— 36.3 = 72.6ย kN, which closely coincides with the manual calculation.

The bolt resistances use formulas from ASย 4100 so that they coincide perfectly, e.g. the bolt shear resistance check (each shear plane is checked separately):

The tearing resistances in manual calculation divides the shear force into components in directions directly towards the ply edge. On the other hand, IDEAย StatiCa uses the direction of the vector in the formula. Only the most decisive check is shown for each bolt.

Bolts in IDEAย StatiCa are loaded also by small tensile forces due to the deformation of plates. These forces are neglected in manual calculation.

Connection to column flange

For the check of bolts at the column flange, the force is applied at the centre of gravity of bolts at the beam web. The bolts are loaded by significant tensile force and this is also decisive for the deformation of the angles. Plastic strain is shown in the figure below. The limit plastic strain is 5ย % according to European code ENย 1993-1-5.

The maximal tensile force is in the upper row of bolts, B8 and B12. Notice the decrease in shear forces of bolts B1โ€“B4 which are loaded only by the shear force and no bending moment. The shear forces in bolts B5โ€“B12 are higher than according to manual calculation: Vf*ย =ย 190ย /ย 8 = 23.75ย kN. This difference is caused by significant deformation of the angles, which also causes the inclination of shear forces.

Joint design resistance

The reserve in the load resistance can be seen by the joint design resistance type of analysis. Due to the yielding of angles, the reserve is low. The joint would fail at load factor 103.4ย %, i.e. shear force Vf*ย =ย 196.5ย kN.

Stiffness

The stiffness of the connection can be determined by setting the type of analysis to "Stiffness", setting the beam as the analyzed member, and setting the correct "Theoretical length" of analyzed member (usually the beam span, centre to centre of columns). The software calculates the secant stiffness at the set load and the initial stiffness at 2/3 Mj,Rd, up to which the momentโ€“rotation diagram is assumed linear. The joint is classified according to the initial stiffness Sj,ini.

Conclusion

IDEAย StatiCa Connection provides similar results to the manual calculation. It requires engineering judgement in determining the position of shear load but all checks are performed quickly and automatically. The forces in bolts are affected by the deformation of plates and the difference may be significant if plates are yielding. The forces acting on components are for this reason generally higher than according to manual calculation with the assumption of small deformations.