Ultimate limit state
The ultimate limit state is reached when the strain for buckling susceptible members has reached 5% or when the solver stops converging because the maximum load has been reached.ย
Using the LBA analysis, ย factor ฮฑcrย (smaller or greater than 15) tells you whether to use only the MNA or GMNIA analyses.
LBA >15: only MNA (materially non-linear analysis) is needed (100% applied) and the results for the MNA Plates have to be less than 5 %
LBA <15: MNA is a must, the ย GMNIA (Geometrically and materially nonlinear analysis with imperfections) ย is needed, and the GMNIA Plates' results (including the imperfections) must be less than 5 %.

Serviceability limit state
Design codes provide limits for deflection in the serviceability limit state. These can be checked by comparing the deflection of the analyzed members to the limits.ย

usum - vector sum of deflection (ux, uy, uz) at the given point
Watch our product engineer Vit modeling a transverse beam of a railway bridge and analyzing it in Member.
Want to improve your skills? Visit our Campus
Learn how to use IDEA StatiCa effectively with our self-paced e-learning courses
Start learning