Welded splice
SteelConnection designVerificationsAISC (USA)CBFEM

Welded splice connection (AISC)

This article is also available in
ENCSDEESFRITPTNLHURO

The resistance of a multi-oriented weld group is verified on an example of a welded splice connection.

Sub-code: LRFD

Type of connection: Concentrically loaded multi-oriented weld group

Unit system: Metric

Designed acc. to: AISC 360-16

Investigated: Welds

Plate Materials: Plate and column – ASTM A572 – Gr. 50

Welds: Leg size = 3 mm, electrode E70XX

Geometry:

Welded splice

Member thickness: 16 mm

Splice thickness: 12 mm

Applied forces:

Simple welded connections are loaded by tension to be utilized at 100 %. Welds are designed to be the weakest component.

Procedure:

Concentrically loaded splice connection with weld groups consisting of elements with a uniform leg size that are oriented both longitudinally and transversely to the direction of applied load is loaded by tension and is designed so that welds fail first. The joint is loaded for the weld to be utilized at 100 % and the load is compared to the weld resistance according to AISC 360 16 – J.2.4.

Manual calculation

The combined strength of the fillet group is determined according to AISC 360-16 – J.2.4 (2).

Base metal strength does not have to be evaluated in case of use of matching electrodes but it is shown here for verification.

An example of a splice connection with the length of longitudinal welds 150 mm and the length of transverse welds 160 mm is shown in the table below:

Comparison:

The results of both IDEA StatiCa Connection design and computation according to AISC 360-16 give nearly identical values in case of weld metal strength (98–101%). With consideration of base metal check, IDEA is slightly conservative (93–94%). Using finite element analysis and the approach of checking the most stressed element of the weld, there is no need for any manual reduction of weld resistance due to weld orientation.

Subscribe to our newsletter

Company

  • About us
  • Partnerships
  • Job openings
  • Patented technology for structural engineers

Resources

  • Customer projects
  • Case studies
  • IDEA StatiCa Connection Library
  • Concrete verifications

Legal

  • IDEA StatiCa END USER LICENSE AGREEMENT
  • Privacy policy
  • Terms of Services – IDEA StatiCa Viewer
  • Licensing

Help

  • Contact
  • Get price quote
  • IDEA StatiCa Specialists
  • Download the latest version
FacebookInstagramLinkedInYouTube

© IDEA StatiCa 2009-2026

Trusted and used worldwide by engineers, fabricators & consultants.