Idea Statica
  • Steel
  • Concrete
  • Support & Learning
  • Pricing
  • Company
  • Steel overview
  • Connection design
  • Member design
  • Parametric design
  • Steel case studies
  • Concrete overview
  • Walls and D-regions
  • Anchoring design
  • Concrete case studies
  • BIM Overview
  • Supported integrations
  • Checkbot
  • Viewer
  • APIs
  • Support Center
  • E-learning & certification
  • Blog
  • Downloads & Licensing
  • Plans
  • Free community tool
  • Enterprise customers
  • Students & educators
  • How much will you save?
  • About us
  • Contact
  • Research & development
  • Authorized resellers
  • Meet our customers
  • Career
  • Steel
    Steel overviewConnection designMember designParametric designSteel case studies
  • Concrete
    Concrete overviewWalls and D-regionsAnchoring designConcrete case studies
  • BIM OverviewSupported integrationsCheckbotViewerAPIs
  • Support & Learning
    Support CenterE-learning & certificationBlogDownloads & Licensing
  • Pricing
    PlansFree community toolEnterprise customersStudents & educatorsHow much will you save?
  • Company
    About usContactResearch & developmentAuthorized resellersMeet our customersCareer
14-Day Trial
14-Day Trial

Subscribe to our newsletter

Company

  • About us
  • Partners
  • Careers
  • Patent

Resources

  • Customer projects
  • Case studies
  • Connection Library
  • Verification books

Legal

  • EULA
  • Privacy policy
  • California Privacy
  • TOS Viewer
  • Licensing

Help

  • Contact
  • Quote request
  • Resellers
  • Downloads
FacebookInstagramLinkedInYouTube

© IDEA StatiCa 2009-2026

Trusted and used worldwide by engineers, fabricators & consultants.

Support CenterVerification examplesAll welded double-angle connection (AISC)
All welded double-angle connection
SteelConnection designVerificationsAISC (USA)CBFEM

All welded double-angle connection (AISC)

This article is also available in
ENCZDEESFRITPTNLHUROKRPLTHTRVIZH

This verification example takes a connection from AISC Design examples (Version 14.2, revised in April 2016) and compares the results with values obtained in IDEA StatiCa. Here we focus on example II.A 3 of the AISC Design examples which is All welded double-angle connection.

Type of connection: All welded double-angle connection

Unit system: Imperial

Designed acc. to: AISC Steel Construction Manual

Investigated: Welds, base material

Plate Materials: Beam and column – ASTM A992, angles – ASTM A36

Welds: Leg size = 3/16 and 1/4 in, electrode E70XX

Geometry:

Applied forces:

The maximum shear forces are applied for the connection to be utilized at 100 % in IDEA StatiCa Connection.

LRFD: Vz = −228 kN at position 7.5 in

ASD: Vz = −158 kN at position 7.5 in

Procedure:

The example is taken from AISC Design examples (Version 14.2, revised in April 2016) – Example II.A 3 All welded double-angle connection.

The minimum resistance of the welded double-angle connection is that of the weld between column flange and angle – 229 kips (LRFD) and 153 kips (ASD).

IDEA StatiCa Connection

The results of ASD is shown

Von Mises stress [MPa]

Comparison:

The results of both IDEA StatiCa and calculation according to AISC Design examples gives nearly identical values: 228 kips (LRFD) and 158 kips (ASD) in IDEA StatiCa and 229 kips (LRFD) and 153 kips (ASD) in AISC Design Example. The assessment in IDEA StatiCa slightly depends on the position of the shear force. The position near the center of gravity of the angle cross-section was selected.

Open in ViewerDownload