Idea Statica
  • Steel
  • Concrete
  • Support & Learning
  • Pricing
  • Company
  • Steel overview
  • Connection design
  • Member design
  • Parametric design
  • Steel case studies
  • Concrete overview
  • Walls and D-regions
  • Anchoring design
  • Concrete case studies
  • BIM Overview
  • Supported integrations
  • Checkbot
  • Viewer
  • APIs
  • Support Center
  • E-learning & certification
  • Blog
  • Downloads & Licensing
  • Plans
  • Free community tool
  • Enterprise customers
  • Students & educators
  • How much will you save?
  • About us
  • Contact
  • Research & development
  • Authorized resellers
  • Meet our customers
  • Career
  • Steel
    Steel overviewConnection designMember designParametric designSteel case studies
  • Concrete
    Concrete overviewWalls and D-regionsAnchoring designConcrete case studies
  • BIM OverviewSupported integrationsCheckbotViewerAPIs
  • Support & Learning
    Support CenterE-learning & certificationBlogDownloads & Licensing
  • Pricing
    PlansFree community toolEnterprise customersStudents & educatorsHow much will you save?
  • Company
    About usContactResearch & developmentAuthorized resellersMeet our customersCareer
14-Day Trial
14-Day Trial

Subscribe to our newsletter

Company

  • About us
  • Partners
  • Careers
  • Patent

Resources

  • Customer projects
  • Case studies
  • Connection Library
  • Verification books

Legal

  • EULA
  • Privacy policy
  • California Privacy
  • TOS Viewer
  • Licensing

Help

  • Contact
  • Quote request
  • Resellers
  • Downloads
FacebookInstagramLinkedInYouTube

© IDEA StatiCa 2009-2026

Trusted and used worldwide by engineers, fabricators & consultants.

Support CenterKnowledge Base ArticlesTypes of 2D members
Reinforced concreteConcreteKnowledge baseRCSEN (Eurocode)

Types of 2D members

This article is also available in
ENCZDEESFRITPTNLHUROKRPLTHTRVIZH

Slab

According to EN 1992-1-1, art. 5.3.1(4) a slab is a member, for which the minimum panel dimension is not less than 5 times the overall slab thickness. The slab is loaded only by bending moments and shear forces perpendicular to the centroidal plane of the slab. Detailing provisions check is performed according to EN 1992-1-1, art. 9.3.

Shell as a slab – Shell-slab

The geometry is defined similarly to the slab geometry definition.  Unlike the slab, the shell-slab can be loaded by bending and membrane actions. Detailing provisions are checked according to rules for slab (EN 1992-1-1, art. 9.3).

Wall

According to EN 1992-1-1, art. 5.3.1(7) a wall is a member, for which the following principles are not fulfilled:

  • the section depth does not exceed 4 times its width
  • the height is at least 3 times the section depth

The wall is loaded only by membrane action and detailing provisions are checked according to EN 1992-1-1, art. 9.6.

Shell as wall – Shell-wall

The geometry is defined similarly to the wall geometry definition. Unlike the wall, the shell-wall can be loaded by bending and membrane actions. Detailing provisions are checked according to detailing provisions for wall (EN 1992-1-1, art. 9.6).

Deep beam

According to EN 1992-1-1, art. 5.3.1(3) a deep beam is a member for which the span is less than 3 times the overall section depth. The deep beam can be loaded as the wall only by membrane actions. Detailing provisions are checked according to EN 1992-1-1, art. 9.7.