Idea Statica
  • Steel
  • Concrete
  • BIM & Workflows
  • Support & Learning
  • Pricing
  • Company
  • Steel overview
  • Connection design
  • Member design
  • Parametric design
  • Steel case studies
  • Concrete overview
  • Walls and D-regions
  • Anchoring design
  • Concrete case studies
  • BIM Overview
  • Supported integrations
  • Checkbot
  • Viewer
  • APIs
  • Support Center
  • E-learning & certification
  • Blog
  • Downloads & Licensing
  • Plans
  • Free community tool
  • Enterprise customers
  • Students & educators
  • How much will you save?
  • About us
  • Contact
  • Research & development
  • Authorized resellers
  • Meet our customers
  • Career
  • Steel
    Steel overviewConnection designMember designParametric designSteel case studies
  • Concrete
    Concrete overviewWalls and D-regionsAnchoring designConcrete case studies
  • BIM & Workflows
    BIM OverviewSupported integrationsCheckbotViewerAPIs
  • Support & Learning
    Support CenterE-learning & certificationBlogDownloads & Licensing
  • Pricing
    PlansFree community toolEnterprise customersStudents & educatorsHow much will you save?
  • Company
    About usContactResearch & developmentAuthorized resellersMeet our customersCareer
14-Day Trial
14-Day Trial

Subscribe to our newsletter

Company

  • About us
  • Partners
  • Careers
  • Patent

Resources

  • Customer projects
  • Case studies
  • Connection Library
  • Verification books

Legal

  • EULA
  • Global privacy policy
  • California Privacy
  • TOS Viewer
  • Licensing

Help

  • Contact
  • Quote request
  • Resellers
  • Downloads
FacebookInstagramLinkedInYouTube

© IDEA StatiCa 2009-2026

Trusted and used worldwide by engineers, fabricators & consultants.

Support CenterSample projectsInner column with global (Euler) buckling hazzard
Inner column with global (Euler) buckling hazzard
SteelMember designSample projectsMemberEN (Eurocode)

Inner column with global (Euler) buckling hazzard

September 23, 2024
This article is also available in
ENCZDEESFRITPTNLHUROKRPLTHTRVIZH

A simple beam-column segment made of a 6-meter-long HEA300 column and an 8-meter-long IPE500 beam lying on top of it. The beam is stabilized by 5-meter-long RHS 80x80x5 bracing tubes on both sides. This structural segment is located inside a larger building and serves as a load distributor into the rest of the structural system and is loaded at the member axis by a uniformly distributed load of 250 kN/m. All steel is grade S355.

More about the project and comparison with the analytical stability analysis in the webinar recording and a blog.

The structure is analyzed in the IDEA StatiCa Member application.

Download